N'ERGY controls the development of electromagnetic components working in hard conditions:
  • High frequency
  • High voltage
  • High temperature functioning

Development of prototypes to validate our products.

Production plant with more than 30 winding machines (linear or core machines, magnetic circuits laminations machines)

Moulding under vacuum and pressure, impregnation under vacuum and pressure according to technical data.

Control of the products with usual means of tests and 2 automated measurement benches.

Measurement of partial discharges of your products.

 
 
Smothing choke
L nominal : 3 x 700 µH, Current : 29 Aeff 400 Hz, Class : H, Weight : 4,3 kg, Part number : F30877.


Smothing choke
L nominal : 45 µH, DC Current : 367,5 Adc, I ripple : 45 Apkpk 20 kHz, Saturation : 1,1 In 1 heure, Class : H, Weight :25,5 kg, Part number : F31418.


Transformer
Power : 2 × 75 kVA, Frequency : 18 kHz, Primary : 560-678 Veff, Class : F, Weight : 120 Kg, Part number : F09590.


Smothing choke
L nominal : 200 µH, DC Current : 200 Aeff, I ripple : 30 Aeff 5 kHz, Saturation : L>100µH à 2 In, Class : H, Weight : 27 kg, Part number : F31311.


Smothing choke
DC Current : 60 Aeff, I ripple : 6 Aeff - 5 kHz, Saturation : L>300µH à 2 In, Class : H, Weight : 9,9 kg, Part number : F31312.


Transformer
Power : 35 kVA, Frequency : 50 Hz, Primary :3 x 380V delta, Secondary :3 x 380V wye, Class : H, Standard :EN 60742, Weight : 235 kg, Part number : F08973.


Transformer
Power : 480VA, Frequency : 2.9 kHz, Primary : 140 V, Secondary : 2x12V, Class : F, Standard : CEI 910, Weight : 0.5 kg, Part number : F09515.